CONFAST®
1/4" x 4" Split Drive Flat Zinc Plated, 100/Box
- SKU:
- SDF144
- UPC:
- 820274001868
- Availability:
- Contact us for information, see page for alternatives.
Description
Products Features
- TAMPERPROOF: Anchor cannot be removed; provides security for item being attached
- FLAT COUNTERSUNK HEAD: Ideal for fastening wood to concrete where head of the anchor sits flush with surface of the wood
- NO SPECIAL TOOLS NEEDED: Drill the hole drive with a hammer; fast and simple
- ONE DIAMETER AND SEVEN LENGTHS: Wide selection options will meet most application requirements
- WIDE RANGE OF LENGTHS: The right fastener for the correct application
Products specifications
Bit Size | 1/4" |
Box Qty | 100 |
Minimum Embedment | 1-1/8" |
Head Type | Flat Countersunk |
Primary | Concrete only |
Minimum Edge Distance | 1-1/4" |
Maximum Fixture Thickness | 2-7/8" |
Minimum Fixture Hole Diameter (In Place) | 3/8" |
Brand Name | CONFAST® |
Minimum Spacing | 2-1/2" |
2000 PSI Concrete - Pull-Out (lbs.) * | 990 |
2000 PSI Concrete - Shear (lbs.) * | 1248 |
Diameter | 1/4" |
Length | 4" |
Material | Carbon Steel Zinc Plated |
Environment | Dry |
Type | Male |
* Values shown are average ultimate values and are offered only as a guide and are not guaranteed. A safety factor of 4:1 or 25% is generally accepted as a safe working load
Installation Video
Installing a 1/4" (four inches) x 4" (four inches) Split Drive Flat Zinc Plated - Drill a 1/4" hole into the concrete using a carbide-tipped bit that meets ANSI Standards B212.15.
- Drill the hole a 1/2" deeper than the anchor will penetrate the concrete, making sure the minimum embedment requirements of 1-1/8" is met.
- The hole can be drilled while the fixture is in place. The minimum hole in the fixture for the 1/4" (four inches) x 4" (four inches) Split Drive Flat Zinc Plated is 3/8".
- Clean the hole with a wire brush, vacuum, compressed air, or a blow-out bulb.
- Insert the 1/4" (four inches) x 4" (four inches) Split Drive Flat Zinc Plated through the material to be fastened and into the hole, ensuring that the bottom of the head is sitting flush with the fixture plate.
- Hammer the anchor until the head of the anchor is tight against the item being fastened.
- Always use proper personal protective equipment per manufacturer's and OSHA instructions.
Additional Information
Bit Size: |
1/4" |
Minimum Embedment: |
1-1/8" |
Type: |
Male |
Primary: |
Concrete only |
Environment: |
Dry |
2000 PSI Concrete - Pull-Out (lbs.) *: |
990 |
2000 PSI Concrete - Shear (lbs.) *: |
1248 |
Diameter: |
1/4" |
Length: |
4" |
Material: |
Carbon Steel Zinc Plated |
Box Qty: |
100 |
Minimum Spacing: |
2-1/2" |
Minimum Edge Distance: |
1-1/4" |
Maximum Fixture Thickness: |
2-7/8" |
Minimum Fixture Hole Diameter (In Place): |
3/8" |
Head Type: |
Flat Countersunk |
Brand Name: |
CONFAST |